Waste Treatment Plant for Chemical Industry
Product Details:
- Recycle Rate >95%
- Ph Level 6.5 to 8.5 (adjustable)
- Water Out Conductivity <10 S/cm
- Water in conductivity Up to 5000 S/cm
- Flow Rate 1 to 30 m/hr
- Technology Physico-Chemical, Biological, and Advanced Oxidation Processes
- Power Consumption 7-45 kW, based on capacity
- Click to View more
Waste Treatment Plant for Chemical Industry Price And Quantity
- 100000 - 10000000 INR/Piece
- 1 Piece
- Easy maintenance with access ports
- Coagulation, Flocculation, Screening
- Online pH, Flow, and TDS Monitoring
- 5°C to 55°C
- Available for installation and maintenance
- Automatic Sludge Dewatering
- Standard Industrial Grey/Custom
- 15+ Years
- Overload Protection, Emergency Shutoff
- PLC/SCADA Automated Control Panel
- Compact, Suitable for limited space applications
- UV/Chlorination, Polishing Filters
- Customizable as per site
- Meets local pollution control board norms
Waste Treatment Plant for Chemical Industry Product Specifications
- >95%
- 1 to 500 m/day
- Customizable as per need
- 1 to 30 m/hr
- Industrial chemical process effluent
- Physico-Chemical, Biological, and Advanced Oxidation Processes
- 7-45 kW, based on capacity
- Up to 5000 S/cm
- <10 S/cm
- 6.5 to 8.5 (adjustable)
- Waste Treatment Plant
- Skid Mounted / On-site
- Stainless Steel / FRP
- Corrosion Resistant, High Efficiency, Low Maintenance
- 220-440 V
- Electric
- Automatic
- Motor Driven
- 50-60 Hz
- <70 dB
- Up to 99%
- Up to 99%
- Multi-Grade / Activated Carbon / Cartridge
- Effluent Treatment in Chemical Industries
- Centrifugal / Submersible / Dosing
- Easy maintenance with access ports
- Coagulation, Flocculation, Screening
- Online pH, Flow, and TDS Monitoring
- 5°C to 55°C
- Available for installation and maintenance
- Automatic Sludge Dewatering
- Standard Industrial Grey/Custom
- 15+ Years
- Overload Protection, Emergency Shutoff
- PLC/SCADA Automated Control Panel
- Compact, Suitable for limited space applications
- UV/Chlorination, Polishing Filters
- Customizable as per site
- Meets local pollution control board norms
Waste Treatment Plant for Chemical Industry Trade Information
- 10 Piece Per Month
- 15-30 Days
Product Description
Waste treatment plant for chemical industry treats and disposes the different wastes generated by chemical manufacturing processes. Solid, liquid, and gaseous chemical refuse can all be divided into these three categories. Chemical stabilization, landfilling, or incineration are all options for treating solid refuse. Physical, chemical, and biological processes like sedimentation, coagulation, flocculation, oxidation, and biodegradation can all be used to handle liquid waste. Absorption, adsorption, or incineration are all treatment options for gas residue. Waste treatment plant for chemical industry is composed of clarifiers, filters, reactors, scrubbers, storage tanks, mixing tanks, settling tanks, and incinerators.
Specifications:
- Bursting pressure: 1.8Mpa
- Testing pressure: 0.9Mpa
Specification
| Feed Flow Rate (cubic-meter/day) | 100 litres/hr - 1000 cubic meter/hr |
| Automation Grade | Automatic |
| Water Source | Industrial Effluent |
| Industry | Leather Industry, Dairy Industry, Chemical/Petroleum Industry, Distillery, Automobile, Slaughter House, Sugar Industry, Pharmaceutical Industry, Paper Mills |
| Brand | Kings Eva |
| Condition | New |
| Treatment Stages | Preliminary Treatment, Tertiary Treatment, Primary Treatment, Disinfection, Secondary Treatment |
| Installation Type | Completes Civil work with Installation, Containerized Plug & Play, Prefabricated |
| Material | Fibre |
| Number of Filtration Passes | 8 |
| Plant Type | Effluent Treatment Plant |
| Warranty | 5 years |
Advanced Automated Treatment
Utilizing PLC/SCADA control panels, our plant ensures precise monitoring and process automation, including real-time pH, flow, and TDS management. The design integrates overload protection, emergency shutoff, and full online diagnostics for operational safety and reliability.
Efficient Space Utilization
Engineered for compactness, the plant can be skid-mounted or installed on-site, making it suitable for locations with limited space. Maintenance access points and modular construction support quick and simple servicing, minimizing downtime and operational disruptions.
Comprehensive Multi-Stage Process
The treatment process includes coagulation, flocculation, screening, followed by advanced UV or chlorination, and polishing filtration, ensuring rigorous contaminant removal. Automatic sludge dewatering and high recycle rates contribute to effective solids management and water recovery.
FAQs of Waste Treatment Plant for Chemical Industry:
Q: How does the waste treatment plant ensure compliance with local pollution control board norms?
A: The system is engineered to meet or surpass stringent local discharge norms by combining advanced physico-chemical, biological, and oxidation processes. Online monitoring of water quality parameters ensures consistent legal compliance.Q: What pre- and post-treatment options are incorporated in this plant?
A: Pretreatment includes coagulation, flocculation, and screening, while post-treatment features UV or chlorination, polishing filters, and reliable sludge handling through automatic dewatering, ensuring high purification standards.Q: When should maintenance be performed on this plant?
A: Maintenance schedules are determined based on operational hours and influent characteristics; however, the easy-access ports and online diagnostics facilitate routine inspection and preventive maintenance with minimal downtime.Q: Where can the waste treatment plant be installed?
A: Its compact, customizable footprint allows installation in a range of settings including skid-mounted or on-site, particularly benefiting chemical industry facilities with space constraints.Q: What is the maximum volume and flow rate the plant can handle?
A: The plants capacity is customizable between 1 and 500 m/day, with flow rates ranging from 1 to 30 m/hr, accommodating various industrial scales and effluent loads.Q: How are automation and monitoring achieved in the plant?
A: The systems PLC/SCADA panel manages operational sequences, process safety, and critical parameter measurements (such as pH, flow, and TDS), ensuring efficient and safe plant operation.Q: What are the key benefits of using this waste treatment plant for the chemical industry?
A: Users benefit from high purification (up to 99%), over 95% water recovery, robust operational safety, minimal maintenance requirements, and reliable after-sales service, making it ideal for modern chemical industry needs.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+